盐酸萘乙二胺分光光度法测定环境空气中氮氧化物含量的不确定评定

Assessment on the Uncertainty of Nitrogen Oxides in the Air Monitoring by N-(1-naphthyl) Ethylene DiamineDiydrochloride Spectrometric Method

  • 摘要: 按照《JJF 1059.1-2012测量不确定度评估与表示》,对分光光度法测定环境空气中氮氧化物含量的不确定度进行评定,按照国家标准分析方法进行样品采集及测定,结果显示,由样品采集过程和分析过程引入的不确定度分别为1.77%和1.67%,合成的相对不确定度为2.43%,其中样品采集过程主要的影响因素为采样器流量和采样器流量校准,分析过程中引入不确定度大小的顺序为:标准曲线配制>样品定容>样品重复测定>仪器测定>工作曲线拟合,测量结果的扩展不确定度为0.0024 mg/m3,测量结果可表示为(0.048±0.002) mg/m3

     

    Abstract: The uncertainty of nitrogen oxides in the air by UV spectrophotometry was evaluated according to Evaluation and Expression of Uncertainty in Measurement(JJF 1059.1-2012).The samples were collected and determined by national standard analysis method.It showed that the relative standard uncertainty in sampling and analysis process were 1.77% and 1.67%,respectively,and the combined relative uncertainty was 2.43%.The main contributors to the sampling uncertainty were the sampling rate of the sampler and the calibration of the sampler flow,the order of uncertainty in the analysis process was standard solution preparation process> sample volume determination> replicated determination of samples> instrument measurements> calibration curve fitting process.The expanded uncertainty of measurement was 0.0024 mg/m3,and the measurement result could be expressed as(0.048±0.002) mg/m3.

     

/

返回文章